Histamine Detection in Mackerel (Scomberomorus Sp.) and its Products Derivatized with 9-Flourenilmethylchloroformate

Authors

  • Muhammad Abdurrahman Munir Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor Author
  • Lee Yook Heng Lee Yook Heng Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor Author
  • Edison Eukun Sage Edison Eukun Sage Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor Author
  • Muhammad MukramMohamed Mackeen Muhammad MukramMohamed Mackeen Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor Author
  • Khairiah Haji Badri Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, Selangor Author

DOI:

https://doi.org/10.21743/pjaec/2021.12.03

Keywords:

Histamine, Mackerel, HPLC, Validation, LOD, LOQ

Abstract

Histamine is commonly present in food containing proteins, like in mackerel. Consuming fish is imperative for the improvement of human muscles. Nevertheless, some studies reported ingesting fish containing histamine more than 50 mg·kg-1 can cause toxicity. This study analyzed and determined the composition of histamine in mackerel and its products commonly consumed in Malaysia, especially on the East Coast of Malaysia. These included processed mackerel such as canned products, satay (skewed fish) and keropok lekor (fish cake/ cracker). Histamine analysis was performed using High Performance Liquid Chromatography (HPLC) equipped with a fluorescence detector. A derivatizing reaction was applied to increase the sensitivity of HPLC to histamine using 9-flourenilmethylchloroformate (FMOC-Cl). The chromatographic separation was achieved in 15 min. Method validation was in accordance to Commission Decision 657/2002/CE. The linear range was at 0.16 – 5.00 μg·mL-1 (histamine) with the LOD at 0.10 μg·mL-1 and LOQ at 0.30 μg·mL-1. Method applicability was checked on seven real samples involving raw, cooked, and dry products, yielding acceptable recovery.

Downloads

Download data is not yet available.

Published

2021-12-31

How to Cite

(1)
Histamine Detection in Mackerel (Scomberomorus Sp.) and Its Products Derivatized With 9-Flourenilmethylchloroformate. Pak. J. Anal. Environ. Chem. 2021, 22 (2), 243-251. https://doi.org/10.21743/pjaec/2021.12.03.

Similar Articles

1-10 of 37

You may also start an advanced similarity search for this article.